VS2 series current mode voltage sensor is a device based on the principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC AC or pulsed currents.
Electrical data (Ta=25ºC±5ºC,RL=2KΩ,CL=10000PF) |
Type |
VS2-50V |
VS2-100V |
VS2-200V |
VS2-500V |
VS2-800V |
Unit |
Rated voltage(Vpn) |
±50 |
±100 |
±200 |
±500 |
±800 |
V |
Measure range(Vp) |
0-±100 |
0-±200 |
0-±400 |
0-±1000 |
0-±1000 |
V |
Rated output(DC) |
@Vp=±Vpn ±20±1% |
mA |
Turns ratio(Np/Ns) |
4000:1000 |
T |
Measure resister |
54~360 |
Ω |
Supply voltage |
±12,±15 |
V |
Power Consumption |
≤20+IpX(Np/Ns) |
mA |
Offset current |
@Vp=0 ±0.2 |
mA |
Offset drift |
@ -40~+85ºC ≤±0.5 |
mA /ºC |
Linearity |
@Vp=0-±Vpn ≤0.2 |
%FS |
Response time |
≤100 |
μS |
Galvanic isolation |
@ 50HZ,AC,1min 2.5 |
KV |
·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Electrochemical
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+V 2:NC 3:-V
4:+15V 5:NC 6:OV 7:-15V 8:IOUT
1. When the voltage will be measured goes through a sensor, the current will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input voltage and the output current are available.
·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000
|
Value |
Unit |
Operating temperature(TA) |
-40 to +85 |
ºC |
Storage temperature (TS) |
-40 to +125 |
ºC |
Mass(approx) (M) |
43 |
g |