LD1 series DC leakage current sensor is a series of new device developed according to principle of electromagnetic induction. Its low current is stable. It is highly insulating between its primary coil and secondary coil. This sensor is used to measure current of signal system, circuit, and leakage monitoring system, as well as to measure current difference.
Electrical data (Ta=25ºC±5ºC ) |
Type |
LD1-10mA |
LD1-20mA |
LD1-30mA |
LD1-50mA |
LD1-100mA |
Unit |
Rated current(Ipn) |
±10 |
±20 |
±30 |
±50 |
±100 |
mA |
Measure range(Ip) |
±12 |
±24 |
±36 |
±60 |
±120 |
mA |
Rated output |
@Ip=±Ipn ±5±1% |
V |
Supply voltage |
±12,±15 |
V |
Power Consumption |
<25 |
mA |
Offset voltage |
@Ip=0 ±50 |
mV |
Offset drift |
@ -40~+85ºC ≤±1.5 |
mV/ºC |
Output drift |
@ -40~+85ºC ≤±1 |
mV/ºC |
Linearity |
@Ip=0-±Ipn ≤1 |
%FS |
Response time |
@50A/μS, 10%-90% ≤50 |
μs |
Galvanic isolation |
@ 50HZ,AC,1min 2.5 |
KV |
·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Electrochemical
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+15V 2:-15V 3:I0UT 4:NC
1. When the current will be measured goes through a sensor, the current will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2.Custom design in the different rated input current and the output current are available.
·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000
|
Value |
Unit |
Operating temperature(TA) |
-40 to +85 |
ºC |
Storage temperature(TS) |
-40 to +125 |
ºC |
Mass(approx) (M) |
40 |
g
|