Zhejiang, China
Business Type:
Manufacturer/Factory, Trading Company, Other
Main Markets:
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, ...
Terms of Payment:
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
OEM/ODM Availability:
Yes
OEM/ODM Service
Sample Available

Voltage Transformer Sensor, Hall Sensor, Hall Voltage Sensor manufacturer / supplier in China, offering Hall Effect (A-VS2) Voltage Transformer Sensor Hall Effect Transducer Manufacturer, 2018 Single Phase Energy Meter ANSI Meter Base Meter Socket Prepaid Kwh Meter, Rh-Da21 120*120 Hole Size Digital Panel Meter Single Row LED Display DC Current Single Phase and so on.

Gold Member Since 2015
Audited Supplier
Supplier Homepage Products Hall Effect current sensor Hall Effect Voltage Sensor/Transmitter Hall Effect (A-VS2) Voltage Transformer Sensor Hall Effect Transducer Manufacturer

Hall Effect (A-VS2) Voltage Transformer Sensor Hall Effect Transducer Manufacturer

Get Latest Price
Min. Order / Reference FOB Price
10 Pieces US $16-18/ Piece
Production Capacity: 100000 PCS /Year
Transport Package: Export and Air-Worthy Standard Carton
Payment Terms: L/C, T/T, D/P, Paypal, Money Gram, Western Union
Voltage Type: DC Voltage
Measuring Principle: Hall Type
Output Signal Type: Analog Type
Material: Mixture
Accuracy Grade: 0.5G
IP Rating: IP65

You Might Also Like

Loading...

Basic Info

Model NO.: A-VS2
Certification: ISO
Customized: Customized
Output: Analog Sensor
Usage: Hall Sensor
Theory: Hall Sensor
Courier: DHL, TNT, FedEx
Trademark: HEYI
Specification: IEC 6044-1
Origin: Yueqing China
HS Code: 8542390000

Product Description

A-VS2 series current mode voltage sensor is a device based on the principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC AC or pulsed currents.
Electrical data (Ta=25ºC±5ºC,RL=2KΩ,CL=10000PF)

TypeA-VS2-
50V
A-VS2-
100V
A-VS2-
200V
A-VS2-
500V
A-VS2-
800V
Unit
Rated voltage(Vpn AC)±50±100±200±500±800V
Measure range(Vp AC)0-±1000-±2000-±4000-±10000-±1000V
Rated output@Vp=±Vpn ±20±1%mA
Turns ratio(Np/Ns)3000:1200T
Measure resister54~360Ω
Supply voltage±12,±15V
Power Consumption≤20+IpX(Np/Ns)mA
Offset current@Vp=0 ±0.2mA
Offset drift@ -40~+85ºC ≤±0.5mA /ºC
Linearity@Vp=0-±Vpn ≤0.2%FS
Response time≤20ms
Galvanic isolation@ 50HZ,AC,1min 2.5KV




Applications

·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Electrochemical

Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+V 2:NC 3:-V
4:+15V 5:NC 6:OV 7:-15V 8:IOUT

Directions for use

1. When the voltage will be measured goes through a sensor, the current will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2.Custom design in the different rated input current and the output current are available.

Standards

·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000

General date


ValueUnit
Operating temperature (TA)-40 to +85ºC
Storage temperature(TS)-40 to +125ºC
Mass(approx) (M)43g