Application: Power, Electronic, Instrument
Phase: Single
Core: Core-type Transformer
Cooling Method: Dry-type Transformer
Winding Type: Multi-winding Transformer
Certification: ISO9001-2000, UL, ISO9001, CCC
Samples:
US$ 80/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Other, Group Corporation

Basic Info.

Model NO.
HPT-80
Usage
Single-phase Transformer, Power Transformer
Frequency Characteristics
High Frequency
Shape of Core
OD
Brand
Heyi
Primary Current
200-6300A
Rated Voltage
AC0.66kv
Secondary Current
5A, 1A, 0.1A, 0.05A
Ambient Temperature
-30ºC~70ºC
Power Frequency Withstand Voltage
3000V/1min 50Hz
Transport Package
Corrugated Box/Corrugated Box/Bubble Bag
Specification
PA66
Trademark
HEYI
Origin
Liushi, Yueqing, Zhejiang Province, China
HS Code
8504311000
Production Capacity
50000

Product Description

300A-2000A Protective Transformer Split Core 5p 10p Hpt-80 Equipment Protection300A-2000A Protective Transformer Split Core 5p 10p Hpt-80 Equipment Protection300A-2000A Protective Transformer Split Core 5p 10p Hpt-80 Equipment Protection 
HPT-80
Bus type/mumbers 80X10/1-2
Accurency: 5P/10P 10 15 20
P/S(A) Capacity
300/5A 2.5 - -
400/5A 5 2.5 2.5
500/5A 5 5 2.5
600/5A 5 5 2.5
750/5A 10 5 5
800/5A 10 5 5
1000/5A 15 7.5 5
1200/5A 15 7.5 5
1500/5A 15 10 5
2000/5A 15 10 5
300/1A 5 - -
400/1A 10 5 -
500/1A 10 5 5
600/1A 15 10 5
750/1A 15 10 5
800/1A 15 10 5
1000/1A 20 10 5
1200/1A 20 10 5
1500/1A 20 10 5
2000/1A 20 10 5
Product features

shell is made of flame-retardant, 140 temperature-resistant imported polycarbonate injection molding.
The core is wound from oriented cold-rolled silicon steel strip.
The secondary conductor is high-strength electromagnetic enameled wire.
The product structure is novel, beautiful in appearance, easy to install,small in size, light in weight, high in accuracy,
and large in capacity.

Application

It is used to collect low-voltage overload and short-circuit signals, and is used with protection relays.
The primary measurement range is 200-6300A, and the secondary output is 5A, 1A.
Collect low-voltage overload and short-circuit signals, which can be used in conjunction with the motor protection unit.
Used in places where there is no direct rain or snow, no serious pollution and severe vibration.



300A-2000A Protective Transformer Split Core 5p 10p Hpt-80 Equipment Protection300A-2000A Protective Transformer Split Core 5p 10p Hpt-80 Equipment Protection300A-2000A Protective Transformer Split Core 5p 10p Hpt-80 Equipment Protection300A-2000A Protective Transformer Split Core 5p 10p Hpt-80 Equipment Protection300A-2000A Protective Transformer Split Core 5p 10p Hpt-80 Equipment Protection300A-2000A Protective Transformer Split Core 5p 10p Hpt-80 Equipment Protection300A-2000A Protective Transformer Split Core 5p 10p Hpt-80 Equipment Protection

How to Order?
1. Please let us know what kind of model, color, poles and rated current etc.
2. Proforma invoice (PI) will be sent to you.
3. Please check and confirm the PI.
4. Once we confirmed the order, please pay it soon.
5. After full payment, all goods will be sent to you in 6-10 days as usual.
6. OEM/ODM is welcomed. Free OEM for more than 5000 sets orders.
 
Shipping:
1. Products are shipped via UPS / DHL / EMS / HK EMS / FedEx / TNT and so on expresses (door to door).
2. We Provide Drop shipping Service.
3.5 days delivery upon receiving payment if the qty is lower than 1000PCS and it is not customized products.
4. In order to ensure you receive your order tax free upon import, we declare lower value.
5. Shipping via EMS. UPS. FedEx and TNT express usually takes 3~7days dependent on the destination country.
 
Payment:
1. We accept Western Union and T/T
2.30% deposit and 70% before shipping
3. No payment collection. We only can deliver goods after getting full payment.
 
Warranty:
1. We provide 1 year warranty.
2. If the product is defective, please notify us within 3 days of delivery.
3. All products must be returned on their original condition, in order to qualify for a refund or exchange of goods
 

Contact us:
Send your Inquiry Details in the Below, Click "Send" Now!
YOUR BENEFITS IS OUR BUSINESS!!!

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Other, Group Corporation
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
OEM/ODM Availability
Yes