Zct Type Zero Phase Sequence Current Transformer Ground-Fault Current Detection Device

Product Details
Customization: Available
Type: Electromagnetic
Output Signal Type: Current Signal
Still deciding? Get samples of US$ 5/Piece
Request Sample
Manufacturer/Factory, Trading Company, Other, Group Corporation
Gold Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
OEM/ODM Availability
Yes
  • Zct Type Zero Phase Sequence Current Transformer Ground-Fault Current Detection Device
  • Zct Type Zero Phase Sequence Current Transformer Ground-Fault Current Detection Device
  • Zct Type Zero Phase Sequence Current Transformer Ground-Fault Current Detection Device
  • Zct Type Zero Phase Sequence Current Transformer Ground-Fault Current Detection Device
  • Zct Type Zero Phase Sequence Current Transformer Ground-Fault Current Detection Device
  • Zct Type Zero Phase Sequence Current Transformer Ground-Fault Current Detection Device
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
ZCT type Zero
Material
Ceramics
Accuracy Grade
0.2G
Application
Switching Power Supply
IP Rating
IP22
Certification
CE
Customized
Non-Customized
Transport Package
Box
Specification
78MM*62.5MM*24.2MM(ZCT ZERO)
Trademark
HEYI
Origin
Wenzhou, Zhejiang
HS Code
8504311000
Production Capacity
50000pieces/Year

Product Description

Product Description

Zero sequence current transformer HY-ZCT is a current transformer specially used to measure or detect the zero sequence component of current in three phase power system.
Unlike common transformers, which are primarily used to measure phase currents, HY ZCT focus on capturing zero sequence currents. This zero sequence component indicates an unbalance or fault condition in the system. HY-ZCT zero sequence current transformer has unique characteristics that make it suitable for specific applications related to fault detection, protection and system monitoring.

Zero Sequence Sensitivity: The HY-ZCT is constructed to have high sensitivity to zero sequence currents and low sensitivity to positive and negative sequence currents. This enables them to accurately measure and detect zero sequence faults, such as ground faults, which are critical to maintaining system safety.

Symmetrical Core Design: HY-ZCT typically use a symmetrical core design to ensure equal magnetic coupling for all three phases. This design reduces the error caused by magnetic unbalance and improves the accuracy of zero sequence current measurement.

High Linearity: The HY-ZCT is designed to provide a linear output over a wide range of zero sequence current. This linearity is critical for accurate fault detection and coordination with protective relays.

Wide frequency range: HY-ZCT is capable of measuring zero sequence current over a wide frequency range, including power system frequencies and harmonics. This versatility enables them to capture and analyze various types of faults and system conditions.

Application:

  • Widely applied to relaying protection field;
  • Adoption of ABS flame-retardant plastic shell;
  • Epoxy resin casting encapsulation, strong insulation and isolation capability, moisture proof and seismic resistance;
  • Ground Fault Detection: One of the main applications of the HY-ZCT is ground fault detection. By measuring zero sequence current, these transformers can identify the presence of ground faults, which occur when current flows from a phase conductor to ground. Timely detection of ground faults is critical to preventing equipment damage, electrical hazards and system failures.
  • Unbalanced load monitoring: HY-ZCT is used to monitor and analyze unbalanced loads in three phase systems. By measuring the zero sequence current, they can provide valuable information about the current distribution of the individual phases. This data helps identify load imbalances that can lead to inefficient power consumption, voltage fluctuations, and equipment overheating.
  • Relay protection coordination: HY-ZCT plays a vital role in relay protection coordination. By accurately measuring the residual current under fault conditions, they provide input to protective relays to initiate appropriate protective action. This coordination helps isolate faulty parts of the system, minimizing downtime and protecting equipment from damage.
  • Ground Fault Protection Schemes: The HY-ZCT is an integral part of various ground fault protection schemes such as high impedance grounded and low impedance grounded systems. These schemes rely on HY-ZCT to detect and mitigate ground faults, ensuring electrical system safety and reliability.

To sum up, the zero sequence current transformer is a special transformer specially designed for measuring and detecting the zero sequence component of the current in the three phase power system. Its unique characteristics such as zero sequence sensitivity, symmetrical core design, high linearity and wide frequency range make it useful in applications such as ground fault detection, unbalanced load monitoring and relay coordination. By accurately capturing zero sequence currents, HY-ZCT help maintain electrical safety, prevent equipment damage, and improve overall system reliability.

Features:

Detection of unbalanced current: ZCT is designed to measure the unbalanced current in a three-phase electrical system, which is the sum of the three phase currents. This allows them to detect ground faults, which can occur when a fault current flows from one or more of the phase conductors to ground.
High sensitivity: ZCT is highly sensitive and can detect even small amounts of ground fault current. This helps to prevent damage to equipment and reduce the risk of electric shock to personnel.
Accuracy: ZCT is designed to provide accurate measurements of the zero-sequence component of the current, even in the presence of high levels of noise or interference.
Non-intrusive installation: ZCT is typically installed around the neutral conductor of a three-phase system, which means that they can be installed without the need to break the circuit or interrupt power to the load.
Frequency response: ZCT is designed to operate over a wide range of frequencies, typically from 50Hz to 400Hz, which makes them suitable for use in a variety of applications.
Low burden: ZCT is designed to have a low burden, which means that they do not significantly affect the operation of the circuit or the accuracy of other measurement devices in the system.
 

Model First Current Secondary Current
HY-ZCT-07 10-400mA 6-500mV
Model First Current Secondary Current
HY-ZCT-09 10-400mA 6-500mV
MODEL Specifications Rated Pr.Current(A) Min. Current(mA) Rated Sec. Current (mA) Max current of system window size(mm) Accuracy Class
HY-ZCT-20 0.3A/0.3mA 0.3A 30mA 0.3mA 100A 20mm 0.2/0.5
1A/1mA 1A 30mA 1mA 100A 20mm 0.2/0.5
1A/0.5mA 1A 30mA 0.5mA 100A 20mm 0.2/0.5
MODEL Specifications Rated Pr.Current(A) Min. Current(mA) Rated Sec. Current (mA) Max current of system window size(mm) Accuracy Class
HY-ZCT-30 0.3A/0.3mA 0.3A 30mA 0.3mA 100A 30mm 0.2/0.5
1A/1mA 1A 30mA 1mA 100A 30mm 0.2/0.5
1A/0.5mA 1A 30mA 0.5mA 100A 30mm 0.2/0.5
MODEL Specifications Rated Pr.Current(A) Min. Current(mA) Rated Sec. Current (mA) Max current of system window size(mm) Accuracy Class
HY-ZCT-45 0.3A/0.3mA 0.3A 30mA 0.3mA 100A 45mm 0.2/0.5
1A/1mA 1A 30mA 1mA 100A 45mm 0.2/0.5
1A/0.5mA 1A 30mA 0.5mA 100A 45mm 0.2/0.5
MODEL Specifications Rated Pr.Current(A) Min. Current(mA) Rated Sec. Current (mA) Max current of system window size(mm) Accuracy Class
HY-ZCT-60 0.3A/0.3mA 0.3A 30mA 0.3mA 250A 60mm 0.2/0.5
1A/1mA 1A 30mA 1mA 250A 60mm 0.2/0.5
1A/0.5mA 1A 30mA 0.5mA 250A 60mm 0.2/0.5
MODEL Specifications Rated Pr.Current(A) Min. Current(mA) Rated Sec. Current (mA) Max current of system window size(mm) Accuracy Class
HY-ZCT-80 0.3A/0.3mA 0.3A 50mA 0.3mA 400A 80mm 0.2/0.5
1A/0.5mA 0.5A 50mA 0.3mA 400A 80mm 0.2/0.5
1A/0.5mA 1A 50mA 0.5mA 400A 80mm 0.2/0.5
MODEL Specifications Rated Pr.Current(A) Min. Current(mA) Rated Sec. Current (mA) Max current of system window size(mm) Accuracy Class
HY-ZCT-100 0.5A/0.5mA 0.5A 30mA 0.5mA 630A 100mm 0.5
1A/1mA 1A 30mA 1mA 630A 100mm 0.5
1A/0.5mA 1A 30mA 0.5mA 630A 100mm 0.5
MODEL Specifications Rated Pr.Current(A) Min. Current(mA) Rated Sec. Current (mA) Max current of system window size(mm) Accuracy Class
HY-ZCT-150 1A/1mA 1A 30mA 1mA 800A 150mm 0.5
1A/0.5mA 1A 30mA 0.5mA 800A 150mm 0.5
MODEL Specifications Rated Pr.Current(A) Min. Current(mA) Rated Sec. Current (mA) Max current of system window size(mm) Accuracy Class
HY-ZCT-220 1A/1mA 1A 30mA 1mA 2000A 220mm 0.5
1A/0.5mA 1A 30mA 0.5mA 2000A 220mm 0.5
 
Zct Type Zero Phase Sequence Current Transformer Ground-Fault Current Detection Device 

Zct Type Zero Phase Sequence Current Transformer Ground-Fault Current Detection DeviceZct Type Zero Phase Sequence Current Transformer Ground-Fault Current Detection Device

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier