• RCD Sensor Residual Current Device Hyca-F13 for Charging Pile
  • RCD Sensor Residual Current Device Hyca-F13 for Charging Pile
  • RCD Sensor Residual Current Device Hyca-F13 for Charging Pile
  • RCD Sensor Residual Current Device Hyca-F13 for Charging Pile
  • RCD Sensor Residual Current Device Hyca-F13 for Charging Pile

RCD Sensor Residual Current Device Hyca-F13 for Charging Pile

Type: Electromagnetic
Output Signal Type: Digital Output
Production Process: SemiConductor Integrated
Samples:
US$ 35/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
RCD Sensor Residual Current Device Hyca-F13 for Charging Pile pictures & photos
RCD Sensor Residual Current Device Hyca-F13 for Charging Pile
US $29-35 / Piece
Min. Order: 1 Piece
Gold Member Since 2015

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company, Other, Group Corporation

Basic Info.

Model NO.
HYCA-F13
Material
Mixture
Accuracy Grade
0.1G
Application
Switching Power Supply
IP Rating
IP65
Certification
ISO
Customized
Customized
Output
Analog Sensor
Supply Voltage
+-12, +-15
Power Consumption
<25
Galvanic Isolation
@ 50Hz, AC, 1min 2.5
Couier
DHL, TNT, FedEx
Transport Package
Export and Air-Worthy Standard Carton
Specification
IEC 6044-1
Trademark
HEYI
Origin
Yueqing China
HS Code
8542390000
Production Capacity
100000 PCS /Year

Packaging & Delivery

Package Size
10.00cm * 5.00cm * 3.00cm
Package Gross Weight
1.000kg

Product Description

RCD Sensor Residual Current Device Hyca-F13 for Charging PileRCD Sensor Residual Current Device Hyca-F13 for Charging PileRCD Sensor Residual Current Device Hyca-F13 for Charging PileRCD Sensor Residual Current Device Hyca-F13 for Charging PileRCD Sensor Residual Current Device Hyca-F13 for Charging Pile
 
Absolute maximum ratings (not operating)
Electrical data Symbol Unit Specification Conditions
Load dump vervoltage UC V 32 400ms
Over-voltage UC V 25 1 minute
Reverse polarity UC V -16 1 minute
Minimum supply voltage UCmin V 6 Continuous not operating
Maximum supply voltage UCmax V 18 Continuous not operating←
Creepage distance dcp mm 7.2  
Clearance dci mm 6.9  
RMS voltage for AC insulation test Ud KV 2.5 50HZ, 1minute
Insulation resistance Rins 500 500 V    iso 16750-2

High-performance automotive sensor, accurate measurement, strong reliability.
Using innovative technology and advanced functions, intelligent, self-adaptive and high-speed response.
Ensure vehicle safety, prevent accidents, and provide critical data.
Compatible with various vehicle types and systems, flexible customization. Energy saving and environmental protection, improve fuel efficiency and reduce emissions.
Provide comprehensive after-sales support and customer service, including technical support, warranty and quick response.



RCD Sensor Residual Current Device Hyca-F13 for Charging Pile

Featuring a transducer based on Fluxgate technology, the sensor offers exceptional sensitivity and linearity. It operates on a unipolar +12V battery power supply, ensuring compatibility with automotive power systems. Moreover, it supports the widely used CAN2.0B protocol, enabling seamless integration into automotive networks.

The Automotive Current Sensor Fluxgate delivers its output signal through high-speed CAN communication, achieving data rates of up to 500 kbps. This allows for fast and reliable transmission of current measurements within the vehicle's electrical system.

With outstanding advantages, this sensor ensures a total error of just 0.5% across a wide temperature range from -40ºC to 85ºC. It exhibits a minimal offset below 10mA, guaranteeing accurate current readings. The sensor also boasts a wide frequency bandwidth and full galvanic separation, enabling precise measurements and reliable performance.
 

RCD Sensor Residual Current Device Hyca-F13 for Charging PileRCD Sensor Residual Current Device Hyca-F13 for Charging PileRCD Sensor Residual Current Device Hyca-F13 for Charging Pile

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
RCD Sensor Residual Current Device Hyca-F13 for Charging Pile pictures & photos
RCD Sensor Residual Current Device Hyca-F13 for Charging Pile
US $29-35 / Piece
Min. Order: 1 Piece
Gold Member Since 2015

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company, Other, Group Corporation
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
OEM/ODM Availability
Yes