Gold Member Since 2015
Audited Supplier
Yueqing Heyi Electrical Co., Ltd.

Split Current Transformer, Current Trannsformer, Split CT manufacturer / supplier in China, offering Heyi Dp Series Clamp-on CT Split Core Current Transformers 100/5A - 6000/5A Current Transducer for Switchgear, Convenient Installation Single Phase Sts DIN Rail Prepaid Energy Meter, Flexible Tariff Setting Sts DIN Rail Prepaid Energy Meter and so on.

(/ )

Supplier Homepage Product Split Core Current Transformer DP Series Heyi Dp Series Clamp-on CT Split Core Current Transformers 100/5A - 6000/5A Current Transducer for Switchgear

Heyi Dp Series Clamp-on CT Split Core Current Transformers 100/5A - 6000/5A Current Transducer for Switchgear

FOB Price: US $1-40 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $1-40/ Piece
Get Latest Price
Port: Ningbo, China
Production Capacity: 100000 PCS /Month
Payment Terms: L/C, T/T, Western Union, Paypal, Alipay

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: DP-23, DP-58, DP-88, DP-812, DP-816
  • Type: Current Transformer
  • Operation Condition: Indoor
  • Winding Form: Multilayer Honeycomb Type
  • Installation: Active Type
  • Voltage Transformation Principle: Capacitive Type
  • Design Advantage: Clamp on Current Transformer
  • Split Core CT Input: 5-5000A
  • Window Size: Check Specification Below
  • Rated Test Voltage: 3kv AC. (1 Min)
  • Safety Factor: Fs 5
  • Transport Package: Outer Carton with Smaller Inner Carton
  • Origin: Liushi, Yueqing, Zhejiang Province, China
  • Application: Electronic, Instrument, Position Sensor, Audio, Lighting
  • Phase: Single
  • Usage: Protection, Measurement
  • Insulating Medium: Insulating Paper
  • Magnetic Circuit Structure: Single Stage Type
  • Model: (Dp Series) Split Core Current Transformer
  • Accuracy: 0.5 / 1.0
  • Split Core CT Output: 1 / 5A
  • Rated Frequency: 50 / 60 Hz
  • Operating Temperature: -10~50 C
  • Trademark: HEYI
  • Specification: IEC 6044-1
  • HS Code: 8504311000
Product Description
DP Series retro-fit split-core current transformer have been specifically designed to be easy to open and yet maintain the accuracy required for intelligent meters, quick to fit around cables. An internal precision resistor across the secondary winding of the CT provides a low safe voltage output. It can be placed into position easily and without disturbing or disconnecting the main cables it it monitoring.
 

Features                                                                                                                                         

1) Double-screw fastening, safe, easy to install, portable

2) Two built in fixing methods: Base; Busbar mounting

3) Wide inner window, allowing clamping of big cables or bus-bars

4) Wide range of sizes to accommodate all the existing installations.

5) Primary current from 5A to 5000A

 

Specification:   

ProductMODELRatioBurden(VA)AccuracyFrequency(Hz)
0.51.0

Heyi Dp Series Clamp-on CT Split Core Current Transformers 100/5A - 6000/5A Current Transducer for Switchgear

 
DP-23 100/5A/2.5VA50/60Hz
150/5A/2.5VA50/60Hz
200/5A2.5VA5VA50/60Hz
250/5A2.5VA5VA50/60Hz
300/5A5VA5VA50/60Hz
400/5A5VA5VA50/60Hz
 
ProductMODELRatioBurden(VA)AccuracyFrequency(Hz)
0.51.0

Heyi Dp Series Clamp-on CT Split Core Current Transformers 100/5A - 6000/5A Current Transducer for Switchgear
 
DP-58250/5A/2.5VA50/60Hz
300/5A/2.5VA50/60Hz
400/5A2.5VA2.5VA50/60Hz
500/5A2.5VA5VA50/60Hz
600/5A2.5VA5VA50/60Hz
800/5A5VA5VA50/60Hz
1000/5A5VA10VA50/60Hz
 
ProductMODELRatioBurden(VA)AccuracyFrequency(Hz)
0.51.0

Heyi Dp Series Clamp-on CT Split Core Current Transformers 100/5A - 6000/5A Current Transducer for Switchgear
 
DP-88250/5A/2.5VA50/60Hz
300/5A/2.5VA50/60Hz
400/5A2.5VA2.5VA50/60Hz
500/5A2.5VA5VA50/60Hz
600/5A2.5VA5VA50/60Hz
800/5A5VA5VA50/60Hz
1000/5A5VA10VA50/60Hz
 
ProductMODELRatioBurden(VA)AccuracyFrequency(Hz)
0.51.0

Heyi Dp Series Clamp-on CT Split Core Current Transformers 100/5A - 6000/5A Current Transducer for Switchgear
 
DP-812500/5A/2.5VA50/60Hz
600/5A/2.5VA50/60Hz
750/5A2.5VA5VA50/60Hz
800/5A2.5VA5VA50/60Hz
1000/5A5VA10VA50/60Hz
1200/5A5VA10VA50/60Hz
1500/5A5VA10VA50/60Hz
1600/5A5VA10VA50/60Hz
2000/5A5VA10VA50/60Hz
 
ProductMODELRatioBurden(VA)AccuracyFrequency(Hz)
0.51.0

Heyi Dp Series Clamp-on CT Split Core Current Transformers 100/5A - 6000/5A Current Transducer for Switchgear
 
DP-8161000/5A5VA10VA50/60Hz
1200/5A7.5VA10VA50/60Hz
1500/5A7.5VA10VA50/60Hz
1600/5A10VA10VA50/60Hz
2000/5A10VA15VA50/60Hz
2500/5A10VA20VA50/60Hz
3000/5A20VA25VA50/60Hz
4000/5A20VA25VA50/60Hz
5000/5A20VA25VA50/60Hz

Installation      
Heyi Dp Series Clamp-on CT Split Core Current Transformers 100/5A - 6000/5A Current Transducer for Switchgear



Applications  

1) Current measurement, monitoring and protection for electrical wiring and equipment.

2) Current and power measurement for electric motors, lighting, air compressor, heating

and ventilation system, air-condition equipment and automation - control system.

3) Current, power and energy monitoring device.

4) Relay protection device.                                                                                                                                            

 

How to Order?
1. Please let us know what kind of model, color, poles and rated current etc.
2. Proforma invoice (PI) will be sent to you.
3. Please check and confirm the PI.
4. Once we confirmed the order, please pay it soon.
5. After full payment, all goods will be sent to you in 6-10 days as usual.
6. OEM/ODM is welcomed. Free OEM for more than 5000 sets orders.
 
 
Shipping:
1. Products are shipped via UPS / DHL / EMS / HK EMS / FedEx / TNT and so on expresses (door to door).
2. We Provide Drop shipping Service.
3.5 days delivery upon receiving payment if the qty is lower than 1000PCS and it is not customized products.
4. In order to ensure you receive your order tax free upon import, we declare lower value.
5. Shipping via EMS. UPS. FedEx and TNT express usually takes 3~7days dependent on the destination country.
 
 
Payment:
1. We accept Western Union and T/T
2.30% deposit and 70% before shipping
3. No payment collection. We only can deliver goods after getting full payment.
 
 
Warranty:
1. We provide 1 year warranty.
2. If the product is defective, please notify us within 3 days of delivery.
3. All products must be returned on their original condition, in order to qualify for a refund or exchange of goods

FAQ:
1) What is the difference between a moulded case current transformer and a split core current transformer?

A moulded case current transformer is a solid ring of steel in a plastic or resin case and can only be used when you fit the cable through the hole in the middle of the plastic/resin case.
 
A split core current transformer is manufactured with the steel core in two pieces. This enables the core to be separated, allowing you to fit the cores around the cable without disconnecting the cables. The disadvantage with split core current transformers is that they can be larger than standard moulded case and the price is approximately four times more expensive.

2) Which way round do the Current Transformers go?
The current transformers must be fitted and connected in the correct way or the meter will not be accurate. The current transformers are marked on two sides: 'P1' and 'P2.' 'P1' must face the mains side and 'P2' must face the load side. 'S1' must be connected to the main side of the meter and 'S2' to the load side. Refer to appropriate wiring diagram of the meter for correct connections.

3) Can the current transformers be a higher or lower ratio then my maximum load?
The current transformers should ideally be about 80% of the normal running load, thus allowing a 20% allowance of increasing the load in the future.

 

Contact us:
Send your Inquiry Details in the Below, Click "Send" Now!

YOUR BENEFITS IS OUR BUSINESS!!!    

You Might Also Like
Product Groups
Send your message to this supplier
Avatar
Ms. Bethy Cai
Manger
*From:
To: Ms. Bethy Cai
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now