Mini Split Core Current Transformer, Split-Core Current Transformers, Open Type Current Transformer manufacturer / supplier in China, offering Sct Low Voltage Precision Split Core Current Transformers Ma or 333mv Output Clamp on Current Transducer, Convenient Installation Single Phase Sts DIN Rail Prepaid Energy Meter, Flexible Tariff Setting Sts DIN Rail Prepaid Energy Meter and so on.

(/ )

Supplier Homepage Product Split Core Current Transformer SCT Series Sct Low Voltage Precision Split Core Current Transformers Ma or 333mv Output Clamp on Current Transducer

Sct Low Voltage Precision Split Core Current Transformers Ma or 333mv Output Clamp on Current Transducer

FOB Price: US $1-10 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $1-10/ Piece
Get Latest Price
Port: Ningbo, China
Production Capacity: 100000PCS/Month
Payment Terms: L/C, T/T, Western Union, Paypal, Alipay

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: SCT series
  • Type: Current Transformer
  • Operation Condition: Indoor
  • Winding Form: Multilayer Honeycomb Type
  • Installation: Active Type
  • Voltage Transformation Principle: Capacitive Type
  • Window Size: 19*19 Mm / 32*32 Mm / 52*52 Mm
  • Rated Output: 0.333V(AC) or 0-500mA
  • Ratio: ± 1.0%
  • Bobbin: PBT
  • Is_Customized: Yes
  • Transport Package: Export Foam Box
  • Origin: Liushi, Yueqing, Zhejiang Province, China
  • Application: Electronic, Instrument
  • Phase: Single
  • Usage: Protection, Measurement
  • Insulating Medium: Insulating Paper
  • Magnetic Circuit Structure: Single Stage Type
  • Model: Sct Split-Core Current Transformer
  • Rated Input: 5A-5000A
  • Frequency: 50-60Hz
  • Case: PC /UL94-V0
  • Core: Permalloy
  • Trademark: HEYI
  • Specification: CE, ISO, RoHs
  • HS Code: 8504311000
Product Description

Sct Low Voltage Precision Split Core Current Transformers Ma or 333mv Output Clamp on Current Transducer
SCT series retro-fit (split-core) current transformer has been specially designed to facilitate their installation in new or already existing net works. They may be installed without opening any cable or bus-bar circuit. An internal precision resistor across the secondary winding of the CT provides a low safe voltage output. It can save time and the installation costs.
 

Features             

1) Split core design, safe, easy to install, portable.

2) Wide inner window, allowing clamping of big cables or bus-bars

3) Wide range of sizes to accommodate all the existing installations

4) Wires plugs, Audio plugs, Power plugs and so on five kinds of plugs

 

 Specification  

Current Ratio50A/10mA100A/20mA200A/33.3mA200A/0.333V
Primary Current (A)50A100A200A200A
Max. Current (A)60A120A240A240A
Output10mA20mA33.3mA0.333mV
Load Resistance (Ω)50Ω50Ω20Ω/
Turns Ration    
Class1.01.01.01.0
Protection Level7.5V0-P
Insuliation CategoryCATIII
Operating Condition -20ºC ~ +50ºC85%RH, No condensation, IN-house & Any direction installable
Storage Condition -30ºC ~ +50ºC85%RH, No condensation
 
Model                                                      SCT-32
Current Ratio200A/40mA300A/60mA400A/40mA600A/60mA400A/0.333V
Primary Current (A)200A300A400A600A400A
Max. Current (A)240A360A480A720A480A
Output40mA60mA40mA60mA0.333V
Load Resistance (Ω)50Ω50Ω50Ω25Ω/
Turns Ration5000:15000:110000:110000:1/
Class1.01.01.01.01.0
Protection Level7.5V0-P
Insuliation CategoryCATIII
Operating Condition -20ºC ~ +50ºC85%RH, No condensation, IN-house & Any direction installable
Storage Condition -30ºC ~ +50ºC85%RH, No condensation
 
 
Model                                                            SCT-52
Current Ratio500A/25mA600A/30mA1000A/50mA1500A/75mA800A/0.333V
Primary Current (A)500A600A1000A1500A800A
Max. Current (A)600A720A1200A1600A960A
Output25mA30mA50mA60mA0.333V
Load Resistance (Ω)50Ω50Ω50Ω25Ω/
Turns Ration20000:120000:120000:120000:1/
Class1.01.01.01.01.0
Protection Level7.5V0-P
Insuliation CategoryCATIII
Operating Condition -20ºC ~ +50ºC85%RH, No condensation, IN-house & Any direction installable
Storage Condition -30ºC ~ +50ºC85%RH, No condensation
 

Note: The Current Ratio above are common type, that's ok to customise the ration according to customers' requirement.


Graph  
Sct Low Voltage Precision Split Core Current Transformers Ma or 333mv Output Clamp on Current Transducer

 

 Applications           

1) Current measurement, monitoring and protection for electrical wiring and equipment.

2) Current and power measurement for electric motors, lighting, air compressor, heating

and ventilation system, air-condition equipment and automation - control system.

3) Current, power and energy monitoring device.

4) Relay protection device.


 The advantages of HEYI SCT   
Sct Low Voltage Precision Split Core Current Transformers Ma or 333mv Output Clamp on Current Transducer


How to Order?
1. Please let us know what kind of model, color, poles and rated current etc.
2. Proforma invoice (PI) will be sent to you.
3. Please check and confirm the PI.
4. Once we confirmed the order, please pay it soon.
5. After full payment, all goods will be sent to you in 6-10 days as usual.
6. OEM/ODM is welcomed. Free OEM for more than 5000 sets orders. 
 
Shipping:
1. Products are shipped via UPS / DHL / EMS / HK EMS / FedEx / TNT and so on expresses (door to door).
2. We Provide Drop shipping Service.
3.5 days delivery upon receiving payment if the qty is lower than 1000PCS and it is not customized products.
4. In order to ensure you receive your order tax free upon import, we declare lower value.
5. Shipping via EMS. UPS. FedEx and TNT express usually takes 3~7days dependent on the destination country. 
 
Payment:
1. We accept Western Union and T/T
2.30% deposit and 70% before shipping
3. No payment collection. We only can deliver goods after getting full payment. 
 
Warranty:
1. We provide 1 year warranty.
2. If the product is defective, please notify us within 3 days of delivery.
3. All products must be returned on their original condition, in order to qualify for a refund or exchange of goods


Our Commitment:                                                                                                                                                          
BETTER PRICE than other suppliers for you because of Factory Direct Sale;
BETTER QUALITY than before caused by our 10+ years experience about CT;
STOCK IN TRADE awlays own to our Fast & Professional production line;
FAST DELIVERY as awlays made by our GROUP's Enthusiam;
TIMING REPLY in 24 hours all about our TEAM's Passion & Patience.
 
FAQ:
1) What is the difference between a moulded case current transformer and a split core current transformer?

A moulded case current transformer is a solid ring of steel in a plastic or resin case and can only be used when you fit the cable through the hole in the middle of the plastic/resin case.
 
A split core current transformer is manufactured with the steel core in two pieces. This enables the core to be separated, allowing you to fit the cores around the cable without disconnecting the cables. The disadvantage with split core current transformers is that they can be larger than standard moulded case and the price is approximately four times more expensive.

2) Which way round do the Current Transformers go?
The current transformers must be fitted and connected in the correct way or the meter will not be accurate. The current transformers are marked on two sides: 'P1' and 'P2.' 'P1' must face the mains side and 'P2' must face the load side. 'S1' must be connected to the main side of the meter and 'S2' to the load side. Refer to appropriate wiring diagram of the meter for correct connections.

3) Can the current transformers be a higher or lower ratio then my maximum load?

The current transformers should ideally be about 80% of the normal running load, thus allowing a 20% allowance of increasing the load in the future. 

Contact us:
Send your Inquiry Details in the Below, Click "Send" Now!
YOUR BENEFITS IS OUR BUSINESS!!!

You Might Also Like
Product Groups
Send your message to this supplier
Avatar
Ms. Bethy Cai
Manger
*From:
To: Ms. Bethy Cai
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now